风管的安装
1、支吊架安装按风管的中心线对称安装,吊杆进行安全可靠的固定,焊接后的部位应刷油漆。
1. The installation of the hanger is mounted on the center line of the wind pipe, the hanger is fixed safely and reliably, and the paint after the welding should be brushed.
2、立管管卡安装时,应先把最上面的管卡固定好,自上而下。
2, riser clamp installation, should put the top card fixed, from top to bottom.
3、风管较长,安装成排支架时,先把两端安好,以两端的支架为基准,中间各支架用拉线法进行安装。
3, the wind pipe is long, when the bracket is installed, the two ends are installed first, the bracket at both ends is the base, and the middle bracket is installed with the drawing wire method.
4、水平安装 长边≤400毫米,间距≤4米;长边>400,间距≤3米;螺旋风管的支吊架分别为5米和3.75米。
4, the level of the installation of a long edge is less than or equal to 400 mm, distance less than 4 meters; the long side is more than 400, distance less than 3 meters; the spiral wind pipe hanger are respectively 5 meters and 3.75 meters.
5、主、干风管长度超过20米,应设置防止摆动的固定点,每个系统不应少于1个。风管垂直安装时,支吊架间距≤4米,单根至少两个固定点。
5, the main and dry wind pipe length more than 20 meters, should be set to prevent swinging fixed points, each system should not less than 1. The wind pipe vertical installation, support and hanger spacing is less than 4 meters, single at least two fixed points.
6、支吊架不得设置在风口、阀门、检查门及自控机构处,离风口距离应大于200毫米。
6. The hanger should not be set up at the tuyere, valve, check door and self-control mechanism. The distance from the air vent should be more than 200 millimeters.
7、抱箍支架折角应平直,圆形风管圆弧应均匀,抱箍应紧贴并抱紧风管。
7. The folding angle of the hoop bracket should be straight, the circular arc of the circular wind pipe should be uniform, and the hoop should be tightly attached to the pipe and hold tight the wind pipe.
8、保温风管的支吊架宜放在保温层外部,保温风管不得与支吊架直接接触,应垫上坚固的隔热防腐材料,其保温厚度与保温层相同,防止产生“冷桥”。
8, the support and hangers of the thermal insulation air pipes should be placed outside the insulation layer. The insulation air pipes must not directly contact with the supporting hangers. The solid insulation and anticorrosive materials should be laid on the surface. The insulation thickness is the same as that of the insulation layer, so as to prevent the generation of "cold bridge".
风管的连接
The connection of the wind pipe
1、法兰密封垫料选用不透气,弹性好的材料,法兰垫料尽量减少接头,接头形式采用阶梯形,接头处应涂密封胶。
1, flange gasket material is chosen with airtight and elastic material. The flange gasket should be reduced as far as possible, the joint form should be stepped, and the joint should be coated with sealant.
2、法兰连接时,先垫好垫料,然后把两个法兰先对正,穿上几颗螺栓并拧上螺母不要上紧,再用尖冲塞进未上螺栓的螺孔中,把两个螺孔撬正,直到所有螺栓都穿上后,拧紧螺栓。紧螺栓时应十字交叉逐步均匀的拧紧。
2, when the flange is connected, first lay up the padding, then put the two flanges on the right side first, then put on a few bolts and screw up the nuts, do not tighten them up, and then use them to rush into the screw holes which are not up to the bolts, and pry the two holes, until all the bolts are put on, then tighten the bolts. Tighten the bolt and tighten the cross step by step.
3、风管连接好后,以两端法兰为准,检查风管连接是否平直。
3. After the wind pipe is connected well, the two ends flanges are used to check whether the connection of the wind pipe is straight.
4、不锈钢风管法兰连接的螺栓,宜用同材质的不锈钢制成,用普通型的,应喷涂涂料。
4. The bolts connected by the stainless steel wind pipe flange should be made of the stainless steel with the same material, and the paint should be sprayed with the ordinary type.
5、铝板风管连接采用镀锌螺栓,在法兰两侧垫镀锌垫圈。
5. The aluminum plate wind pipe is connected with galvanized bolt, and the galvanized washer is padded on both sides of the flange.
6、非金属风管法兰连接,两法兰端面应平行严密,法兰螺栓两侧应加镀锌垫圈。
6, non-metallic wind pipe flange connection, two flange face should be parallel and strict, flange bolt on both sides should be galvanized gasket.
7、复合材料风管采用法兰连接时,应有防冷“冷桥”措施,连接法兰的螺栓应均匀拧紧,其螺母宜在同一侧。
7. When the compound material wind pipe is connected with the flange, it should have the "cold bridge" measures of anti cooling. The bolts connecting the flange should be tightened evenly, and the nut should be on the same side.
风管的安装
The installation of the wind pipe
1、技术要求,明装水平度 每米≤3mm ,总偏差≤20mm;垂直度每米≤2mm,总偏差≤20mm;暗装,位置应正确,无明显偏差。
1, the technical requirements, with the level of per meter is less than or equal to 3mm, the total deviation is not greater than 20mm; verticality per meter is less than or equal to 2mm, the total deviation is not greater than 20mm; concealed installation location should be correct, no significant deviation.
2、安装顺序:先干管后支管,安装方法:根据实际情况确定。
2, the installation order: the pipe after the first pipe, installation method: according to the actual situation.
可以在地面上连成一定的长度,然后整体吊装,一般可接长至10--12米左右,用倒链或升降机将风管吊到支架上(比较重的风管),也可以把风管一节一节地放在支架上逐节连接。
Can be connected to a certain length on the ground, and then the integral hoisting, generally can be connected to 10--12 meters long, with a chain or lift wind pipe hanging onto the bracket (wind pipe heavier), can also be a section of a wind tube placed on the bracket by section connection.
3、风管穿越需要封闭的防火防爆的墙体或楼板时,应设预埋管或防护套管,其钢板厚度不应小于1.6mm,风管与防护套管之间,应用不燃且对人体无危害的柔性材料封堵。
3, when a wind tunnel passes through a closed fire and explosion proof wall or floor, a buried pipe or protective casing shall be set up. The thickness of the steel plate shall not be less than 1.6mm. The flexible material between the wind pipe and the protective sleeve shall be sealed with no flammable and harmless material to the human body.
4、复合材料风管接缝应牢固,无孔洞和开裂,风管系统安装完毕后,应按系统类别进行严密性检验。
4. The joint of the wind pipe of the composite material should be firm, without holes and cracks. After the installation of the wind pipe system, the tightness inspection should be carried out according to the system category.
风阀的安装
The installation of the wind valve
1、风阀安装前应检查框架结构是否牢固,调节制动、定位等装置是否准确灵活。
1, before the installation of the wind valve should be checked whether the frame structure is firm, and the adjustment of the braking, positioning and other devices is accurate and flexible.
2、风阀的安装同风管的安装,将其法兰与风管或设备的法兰对正,加上密封垫片,上紧螺栓,使其与风管或设备连接牢固严密。
2, the installation of the wind valve and the installation of the air pipe, the flange and the flanges of the air pipe or equipment should be aligned, plus the gasket and tighten the bolts to make it connect tightly with the wind pipe or equipment.
3、风阀安装时,应使阀件的操纵装置便于人工操作,其安装方向应与阀体外壳标注的方向一致。
3. When the valve is installed, the control device of the valve should be easy to operate, and the direction of the installation should be in accordance with the direction of the body's shell.
4、安装完的风阀,应在阀体外壳上有明显和准确的开启方向,开启程度的标志。
4, the installation of the wind valve, the valve body should have a clear and accurate opening direction, the mark of the opening degree.
防火阀的易熔件应安装在风管的迎风侧,其熔点温度应符合设计要求。
A fusible fireproof valve should be installed on the windward side of the wind pipe, the melting temperature should meet the design requirements.